BJHQX - 1044437 EKTAPRINT 2 DEV/REPL LORR-H, PART C
- MSDS: BJHQX
- Manufacturer: EASTMAN KODAK COMPANY
- Product Name: 1044437 EKTAPRINT 2 DEV/REPL LORR-H, PART C
- National Stock Number: 6750-00F013476
Product Identification
Product ID:1044437 EKTAPRINT 2 DEV/REPL LORR-H, PART C
MSDS Date:08/15/1986
FSC:6750
NIIN:00F013476
MSDS Number: BJHQX
Responsible Party
ROCHESTER, NY 14650
Emergency Phone: (717) 722-5151
Info Phone: (717) 722-5151
Cage: 19139
Contractor
Telephone: 716-722-5151/(800) 242-2424
Cage: 19139
Ingredients
WATER, H2O
CAS: 7732-18-5
RTECS: PB4310000
Fraction By Weight: 30-45%
POTASSIUM SULFITE
CAS: 10117-38-1
RTECS: WT3530000
Fraction By Weight: 1-5%
Hazards
LD50 LC50 Mixture:ORAL RAT LD50 = 400 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: LOW CONCENTRATION S CAN
CAUSE RESPIRATORY TRACT IRRITATION. EYES: IRRITATION. SKIN:
IRRITATION, SENSITIZATION, ALLERGIC REACTION. INGESTION: HARMFUL.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: LOW CONCENTRATIONS CAN CAUSE
RESPIRATORY TRACT IRRITATION. SKIN: IRRITATION, ALLERGIC REACTION,
& SENSITIZATION. INGESTION: HARMFUL
Medical Cond Aggravated by Exposure:ALLERGIC REACTION, SENSITIZATION.
First Aid
First Aid:EYES: FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINS & GET MED
ATT. SKIN: FLUSH W/PLENTY OF WATER & WASH W/A NON-ALKALINE (ACID)
TYPE OF SKIN CLEANSER. GET MED ATT. INGESTION: IF CONSCIOUS, RINSE
MOUTH/ INDUCE VOMITING IMMEDIATELY BY GIVING 1OR 2 GLASSES OF
WATER. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. CALL
PHYSICIAN. INHALATION: REMOVE TO FRESH AIR.
Fire Fighting
Flash Point:NONE
Extinguishing Media:WATER SPRAY; DRY CHEMICAL; CO2
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS & FULL
PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:FIRE OR EXCESSIVE HEAT MAY CAUSE
PRODUCTION OF HAZARDOUS DECOMPOSITION PRODUCTS.
Accidental Release
Spill Release Procedures:NEUTRALIZE W/BAKING SODA (SODIUM BICARBONATE)
FLUSH MATERIAL TO SEWER W/LARGE AMOUNTS OF WATER.
Neutralizing Agent:BAKING SODA (SODIUM BICARBONATE)
Handling
Handling and Storage Precautions:AVOID BREATHING VAPOR, CONTACT W/EYES,
SKIN, & CLOTHING. WASH THOROUGHLY AFTER HANDLING. USE W/ADEQUATE
VENTILATION.
Other Precautions:DIRECT INSTANTANEOUS DISCHARGE TO A RECEIVING BODY OF
WATER OF AN AMT OF THIS CHEMICAL WILL RAPIDLY PRODUCE, BY DILUTION,
A FINAL CONCENTRATION OF 0.09 MG/L OR LESS & ISN'T EXPECTED TO
CAUSE AN ADVERS E ENVIRONMENTAL EFFECT.
Exposure Controls
Respiratory Protection:A NIOSH APPROVED ACID GAS RESPIRATOR SHOULD BE
WORN IF NEEDED.
Ventilation:TYPICALLY 10 ROOM VOLUMES PER HOUR IS CONSIDERED GOOD
GENERAL VENTILATION. GOOD MECHANICAL VENTILATION SHOULD BE USED.
Protective Gloves:IMPERVIOUS
Eye Protection:SAFETY GLASSES
Work Hygienic Practices:THE ROUTINE USE OF A NON-ALKALINE (ACID) TYPE
OF SKIN CLEANSER WILL HELP MINIMIZE THE POSSIBILITY OF ALLERGIC
REACTION.
Supplemental Safety and Health
AFTER DILUTION W/A LARGE AMOUNT OF WATER, FOLLOWED BY SECONDARY WASTE,
TREATMENT, THE CHEMICALS IN THIS FORMULATION AREN'T EXPECTED TO
HAVE ANY ADVERSE ENVIRONMENTAL IMPACT.
Chemical Properties
Boiling Pt:B.P. Text:>212F
Vapor Pres:18
Vapor Density:0.6
Spec Gravity:1.138
pH:1.1
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR, LIGHT YELLOW SOLUTION; SHARP SULFUR DIOXIDE
ODOR
Percent Volatiles by Volume:65%
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ALKALI
Stability Condition to Avoid:EXCESSIVE HEAT OR FIRE
Hazardous Decomposition Products:CO2, CO, OXIDES OF NITROGEN & SULFUR
Disposal
Waste Disposal Methods:DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT
TO FEDERAL, STATE, OR LOCAL LAWS. EXPECTED TO HAVE A LOW BIOLOGICAL
OXYGEN DEMAND. COMPONENTS BIODEGRADE OR BIOTRANSFORM TO MATERIALS.
NOT LIKELY TO BI OCONCENTRATE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.